Technical Highlights |
Inputs |
Fuels | Natural Gas, Directed Biogas |
Input fuel pressure | 15 psig |
Fuel required @ rated power | 0.661 MMBtu/hr of natural gas |
Water required (for startup only) | 120 gallons municipal water |
Outputs |
Rated power output (AC) | 100 kW |
Electrical efficiency (LHV net AC) | > 50% |
Electrical connection | 480V @ 60 Hz, 4-wire 3 phase |
Physical |
Weight | 10 tons |
Size | 224" x 84" x 81" |
Emissions |
NOx | < 0.07 lbs/MW-hr |
SOx | negligible |
CO | < 0.10 lbs/MW-hr |
VOCs | < 0.02 lbs/MW-hr |
CO2 @ specified efficiency | 773 lbs/MW-hr on natural gas,
carbon neutral on Directed Biogas |
Environment |
Standard temperature range | 0° to 40° C (extreme weather kit available) |
Max altitude at rated power | 6,000 ft. MSL |
Humidity | 20% - 95% |
Seismic Vibration | IBC 2003: Site Class D |
Location | Outdoor |
Noise @ rated power | < 70 DB @ 6 feet |
Codes and Standards |
Complies with Rule 21 interconnection standards |
Exempt from CA Air District permitting; meets stringent CARB 2007 emissions standards |
Product Listed by Underwriters Laboratories Inc. (UL) to ANSI/CSA America FC 1 |
Additional Notes |
Operates in a grid parallel configuration |
Includes a secure website for you to showcase performance & environmental benefits |
Remotely managed and monitored by Bloom Energy |
Capable of emergency stop based on input from your facility |
0 comments: