| Technical Highlights |
| Inputs |
| Fuels | Natural Gas, Directed Biogas |
| Input fuel pressure | 15 psig |
| Fuel required @ rated power | 0.661 MMBtu/hr of natural gas |
| Water required (for startup only) | 120 gallons municipal water |
| Outputs |
| Rated power output (AC) | 100 kW |
| Electrical efficiency (LHV net AC) | > 50% |
| Electrical connection | 480V @ 60 Hz, 4-wire 3 phase |
| Physical |
| Weight | 10 tons |
| Size | 224" x 84" x 81" |
| Emissions |
| NOx | < 0.07 lbs/MW-hr |
| SOx | negligible |
| CO | < 0.10 lbs/MW-hr |
| VOCs | < 0.02 lbs/MW-hr |
| CO2 @ specified efficiency | 773 lbs/MW-hr on natural gas,
carbon neutral on Directed Biogas |
| Environment |
| Standard temperature range | 0° to 40° C (extreme weather kit available) |
| Max altitude at rated power | 6,000 ft. MSL |
| Humidity | 20% - 95% |
| Seismic Vibration | IBC 2003: Site Class D |
| Location | Outdoor |
| Noise @ rated power | < 70 DB @ 6 feet |
| Codes and Standards |
| Complies with Rule 21 interconnection standards |
| Exempt from CA Air District permitting; meets stringent CARB 2007 emissions standards |
| Product Listed by Underwriters Laboratories Inc. (UL) to ANSI/CSA America FC 1 |
| Additional Notes |
| Operates in a grid parallel configuration |
| Includes a secure website for you to showcase performance & environmental benefits |
| Remotely managed and monitored by Bloom Energy |
| Capable of emergency stop based on input from your facility |
0 comments: